  • The choice of cooling tower depends on these factors!

The choice of cooling tower depends on these factors!

انتخاب برج خنک کننده
Monday, 29 November 2021 / Published in News

The choice of cooling tower depends on these factors!

Many criteria must be considered for the selection of a cooling tower (Cooling tower selection), but the following 3 parameters are very important and vital:

  • Flow rate through cooling tower GPMCT
  • Inlet and outlet water temperature difference from cooling tower  TRange∆
  • The difference between the outlet water temperature of the tower and the humid temperature of the ambient air  TApproach∆

In order to calculate the water flow rate of the cooling tower, the heat output of the cooling tower and the difference between the inlet and outlet temperatures of the tower must be specified.

In compression chillers, the amount of heat generated in the cooling tower is equal to the heat generated in the evaporator and compressor, which is dissipated by the cooling tower.

 

QCT =QEV + QComp

In absorption chillers, the amount of heat generated in the cooling tower is equal to the heat generated in the generator and evaporator, which is dissipated by the cooling tower.

 

QCT =QEV + QGEM

The relationship between the amount of heat generated in the cooling tower and the flow through it is as follows:

 

QCT =500GPM∆TRange

 

برج خنک کننده کوچک

 

In the above relation ∆TRange, which is the difference between the inlet and outlet water temperature of the cooling tower, is determined according to the type of chiller and the manufacturer. The unknown parameter in the above relation is the amount of heat generated in the cooling tower. To calculate it by the ratio of chiller performance coefficient (COP) which is as follows, the amount of heat generated by 1 ton of refrigerant is equal to 12000Btu / hr and then Depending on the refrigeration capacity of the chiller and the product of its multiplication in the number obtained for 1 ton of refrigeration, the amount of heat generated in the cooling tower for the generator in the absorption chiller or the compressor in the compression chiller will be obtained.

 

COP = (12000Btu/hr) / Heat rejection per USRT

 

For example, the coefficient of performance of South Korea Century direct flame absorption chillers with ultra-high efficiency (GH series) is 1.34, so the heat generated in the absorption chiller generator will be equal to:

 

Heat rejection per USRT = (12000Btu/hr) / 1.34

 

As a result, the amount of heat generated in the chamber of the direct flame absorption chiller is equal to 8960Btu / hr. On the other hand, as previously stated, the total heat dissipated in the cooling tower per ton of refrigeration will be equal to the total heat loss in the evaporator and generator chamber, so the total heat dissipation per ton of refrigeration for the cooling tower will be equal to :

 

QCT = QEV + QGEM = 12000+8960 = 20960Btu/hr

 

Assume the selected chiller has a refrigeration capacity of 500 tons, so the GPM value of the cooling tower water will be equal to:

 

QCT =500GPM∆TRange

500*2960 Btu/hr = 500*GMPCT*9F

GPMCT=2328

 

What you can read next

انتخاب چیلر آب خنک یا هوا خنک
Buy a cool air chiller or cold water?
فن کویل کاستی
Cassette fan coil units and its pros and probs
چیلر اتاق سرور
Server chiller and server room cooling equipment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Search here …

Latest articles

  • کامیون حمل گاز مبرد

    What is refrigerant gas and what is its application in different industries ?!

    What is refrigerant gas? Air conditioners gener...
  • سردخانه کوچک

    Classification of industrial refrigeration types based on different characteristics

    In the previous article, the issue of what is a...
  • سردخانه صنعتی چیست

    What is industrial refrigeration and what is its application in industry?

    Industrial refrigeration is defined as a closed...
  • انتخاب چیلر آب خنک یا هوا خنک

    Buy a cool air chiller or cold water?

    One of the important issues of production cente...
  • کاربرد روفتاپ پکیج

    What is the application of Rooftop package in industries and facilities ?!

    Rooftop applications in various places Warm up ...
  • روفتاپ پکیج چیست

    What is a rooftop package and how does it work ?!

    A rooftop package, as its name implies, is a si...
  • نفوذ ویروس در سیستم تهویه مطبوع

    What is the solution to the virus penetration in the air conditioning system ?!

    The virus and its circulation in the air condit...

Sarma Sazan Jamejam is one of the active and leading groups in the installation industry in Iran. It started its career from the early days with a special structure and coherent and relying on a unique unit in order to meet some needs of builders of luxury construction units, including commercial, residential, as well as hospital and hotel projects. The SSJ eng. Company with years of experience and significant presence in various construction projects from the beginning of its establishment has tried to always improve the quality of all its activities by applying correct and innovative management methods in product selection, sales and especially after-sales services to be customers choice.

PRODUCTS

  • Chillers
  • Fan Coils
  • Cooling Tower
  • Duct Split
  • VRF System

COMPANY INFO

Unit 903, 9th floor, Palladium Plus (2), North Bahman st., Moqaddas Ardabili st., Tehran. Iran

+9821-21600
+9821-22037310
+9821-22037311

info@sarmasazan.co

+989120191386

sarmasazan_jam_e_jam

TOP });