Server chiller and server room cooling equipment

Because technology companies recognize the importance of data centers and server rooms, they are investing heavily in first-class equipment. However, these devices generate high levels of heat that can be harmful in many ways. The heat from the operation of this equipment is directed out by air conditioners such as server room chillers to prevent damage and their temperature is controlled for optimal operation.

 

Target server chillers

Server chillers help control the high levels of heat generated by equipment in server rooms. Without this cooling system, it is possible to increase the temperature rapidly, which can destroy important data and hardware. As a result, various cooling technologies have been developed to prevent these losses.

The purpose of these cooling systems is to create and maintain the right environmental conditions for the optimal performance of IT equipment. In addition, server chillers are very important for installing highly centralized server clusters. Because these clusters generate high levels of heat, they are needed to keep the workspace cool. In addition, it allows computer equipment to maximize performance and activity.

 

What is the ideal server room temperature?

Servers can withstand temperatures ranging from 60 to 90 degrees Fahrenheit. However, the best temperature for a server room is 72 degrees Fahrenheit with 45% relative humidity. Maintaining the ideal temperature and humidity of the server room by the chiller allows the servers to work optimally and prevents a sudden increase in heat, thus reducing the possibility of the servers shutting down.

 

Factors to consider for server room cooling!

To maintain the ideal server room temperature, you need to consider some factors. These factors include:

  • Land area
  • Window size and position
  • inhabitants
  • Lighting

By calculating the potential heat that most of these factors can produce, you can get an approximate estimate of the total heat generated by the server room. For example, the more occupants of the room, the more heat is generated. Knowing this estimate will give you an idea of the cooling needs and solutions you can apply.

 

اتاق سرور

اتاق سرور

 

How does a server chiller work?

Generally, a server chiller works by combining tall floors with computer room air conditioning (CRAC) or computer room air conditioners (CRAH). CRAC / CRAH transmits cold air through the inputs of the server and then its components by pressing the space below the upper floors. This cold air exits as hot air and is removed for cooling and recycled to CRAC / CRAH. Some other innovative cooling technologies include:

  • Immersion system: which immerses the hardware in a non-conductive and non-flammable dielectric fluid.
  • Liquid cooler: which exposes the server components directly to the liquid to cool.
  • Direct chip cooling: which directly integrates cold plates with the hardware motherboard for efficient cooling.

 

Server Room Cooling Challenges

Some of the major challenges associated with cooling server rooms include:

  • High power and energy consumption
  • Inefficient use of cooling room space
  • Inefficient operation of the server room chiller due to energy loss due to friction
  • Proximity to cold water sources
  • Poor data center zoning practices

 

Advantages of effective server cooling systems

Significant benefits for the development of effective server cooling systems include:

  • To optimize operations
  • To reduce downtime
  • To protect critical materials and equipment
  • To save time and money

 

Operation optimization

Keeping the server room cool is crucial as it ensures that the servers perform well. Side effects such as equipment damage, communication network disruption and data loss can affect the smooth operation of the data center and its customers. By identifying a cooling technology that is suitable for the needs of heat transfer, better efficiency and performance can be ensured.

 

Reduce downtime

Proper ventilation and cooling systems can prevent malfunctions. Some hardware and software failures are caused by overheating generated by computing equipment that leads to failures. But with a server room chiller, you can avoid this challenge.

 

Equipment protection

Server cooling systems protect equipment from temperature damage. With the constant and proper monitoring known to them, they act as a precaution against the high risks of equipment damage. This continuous maintenance culture allows managers to track room temperature and humidity conditions and equipment to prevent heat damage and thus protect important customer data. In addition, server room chillers help extend the life of equipment.

 

Save time and money

By optimizing server performance, reducing malfunctions, and protecting equipment from damage, data center operators save significant time and money. In addition, by installing proper cooling systems on computer servers, you can avoid the cost of repairing malfunctions, replacing hardware, and other additional heat-related costs.

What you can read next

چیلر جذبی
What is an absorption chiller?
کاربرذهای چیلر گرمایشی
What are the applications of heating chillers in industry ?!
انواع چیلر
Comprehensive guide to different types of chillers (Part 2)

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Search here …

Latest articles

  • کامیون حمل گاز مبرد

    What is refrigerant gas and what is its application in different industries ?!

    What is refrigerant gas? Air conditioners gener...
  • سردخانه کوچک

    Classification of industrial refrigeration types based on different characteristics

    In the previous article, the issue of what is a...
  • سردخانه صنعتی چیست

    What is industrial refrigeration and what is its application in industry?

    Industrial refrigeration is defined as a closed...
  • انتخاب چیلر آب خنک یا هوا خنک

    Buy a cool air chiller or cold water?

    One of the important issues of production cente...
  • کاربرد روفتاپ پکیج

    What is the application of Rooftop package in industries and facilities ?!

    Rooftop applications in various places Warm up ...
  • روفتاپ پکیج چیست

    What is a rooftop package and how does it work ?!

    A rooftop package, as its name implies, is a si...
  • نفوذ ویروس در سیستم تهویه مطبوع

    What is the solution to the virus penetration in the air conditioning system ?!

    The virus and its circulation in the air condit...

Sarma Sazan Jamejam is one of the active and leading groups in the installation industry in Iran. It started its career from the early days with a special structure and coherent and relying on a unique unit in order to meet some needs of builders of luxury construction units, including commercial, residential, as well as hospital and hotel projects. The SSJ eng. Company with years of experience and significant presence in various construction projects from the beginning of its establishment has tried to always improve the quality of all its activities by applying correct and innovative management methods in product selection, sales and especially after-sales services to be customers choice.

PRODUCTS

  • Chillers
  • Fan Coils
  • Cooling Tower
  • Duct Split
  • VRF System

COMPANY INFO

Unit 903, 9th floor, Palladium Plus (2), North Bahman st., Moqaddas Ardabili st., Tehran. Iran

+9821-21600
+9821-22037310
+9821-22037311

info@sarmasazan.co

+989120191386

sarmasazan_jam_e_jam

TOP });